MEA60-Inv-2-BC-System-E-Standard
Complete recording system for micro-electrode arrays on inverted microscopes including 2 amplifiers to record from 60 MEA electrodes and 4 additional channels. With enhanced perfusion equipment and a second two channel temperature controller. Featuring a blanking circuit for simultaneous stimulation and recording without stimulus artefacts.
- Data acquisition computer:
PC configuration 2, with preinstalled hardware, operating system, and software - MC_Rack Program:
Data acquisition and analysis software, including a 2 years maintenance package (software updates and support) - MEA_Select Program:
MEA1060-BC control software, including a 2 year maintenance package (software updates and support) - MC_Card 64:
64-channel PCI-bus data acquisition card, simultaneous 50 kHz sampling on each channel - 68-Pin-Slot:
Interface for 64 analog inputs and power distribution (68-pin MCS Standard connector) - 3-An-Slot:
Interface for 3 analog inputs (3 BNC connectors) - 3-Di-Slot:
Interface for input bits 0, 1, 2 of the 16-bit digital (TTL) channel (3 BNC connectors) - PS20W:
Low-noise isolated power supply with 21 W power and ± 7 V output voltage - MEAS2/1:
MEA Switch 2 to1 for selecting 60 recording channels from two MEA1060 amplifiers - MEA_Switch program:
MEAS2/1 control software, including a 2 year maintenance package (software updates and support) - 2x MEA1060-Inv-BC-Standard amplifier (incl. MEA1060-Inv-BC-PA, FA60SBC and C68x1M):
Probe interface and integrated 60 channel pre- and filter amplifier for 60 electrode MEAs, for inverted microscopes, with blanking circuit, controlled by MEA_Select software.
Gain and bandwidth as specified in the order.
(Standard amplifier specifications:
Gain: 1100, bandwidth: 1 Hz - 3 kHz;
possible amplifier specifications:
Gain: 500-5000, bandwidth: 1 Hz - 10kHz) - C68x2M:
68-pin MCS standard cable, 2 m - 2 x TC02:
2-channel temperature controller for biological samples, set-point temperature reached fast within 30 s to 5 minutes, control temperature range from ambient temperature to +50 °C,
precision controller using PID characteristics - 2 x PH01:
Perfusion cannula with programmable fluid temperature, controlled by TC01/2 - 5 MEAs:
Type and electrode grid as specified in the order (complete catalog range available) - Accessories:
Cable assembly, reference electrodes, test model probe, spare parts, user manuals
Technical specifications as specified in the data sheet unless noted otherwise in the order.