Bundle of Multiwell and MEA2100-60-System.
Multiwell-MEA workstation for recording and analyzing data from multiwell MEA plates. With integrated data acquisition for recording from 288 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and voltage stimulus generator (simultaneous stimulation in all wells possible. Any electrode can be selected for stimulation).
MEA2100 workstation for recording and analyzing data from 60-electrode MEAs (microelectrode array). With integrated data acquisition for recording from 60 MEA electrodes and 8 additional analog channels. Integrated filter amplifier and 3-channel current or voltage stimulus generator.
Complete with interface board, Multiwell-MEA headstage, MEA2100-60 headstage, data acquisition computer with preinstalled software, perfusion kit, and accessories. USB High Speed data transfer with a sampling rate of up to 50 kHz/channel.

 

• Multiwell-MEA headstage:
  - Pre- and filter amplifier with integrated data acquisition and
    analog-digital converter
  - Bandwidth adjustable via software
  - Data resolution 24 bit
  - Direct access to each electrode for stimulation via internal
    stimulus generator.
  - Control of stimulator via the included data acquisition
    software Multiwell Screen
  - Integrated blanking circuit for stimulus artifact suppression
  - Integrated stimulus generators (any electrode can be selected
    for stimulation)
  - Current stimulation at max. +/-1 mA
  - Voltage stimulation at max. +/-10 V
  - Sampling rate max. 50 kHz per channel
  - Integrated heating plate and temperature control
• MEA2100 headstage (MEA2100-HS60):
  - Pre- and filter amplifier with integrated data acquisition and analog-digital converter
  - Bandwidth adjustable via software Multi Channel Suite
  - Data resolution: 24 bit
  - Direct access to each electrode for stimulation via internal stimulus generator.
  - Control of stimulator via the included data acquisition software
  - Current stimulation at max. +/-1.5 mA
  - Voltage stimulation at max. +/-10 V
  - 3 independent stimulus generators
  - Sampling rate max. 50 kHz per channel
  - Integrated heating element (Pt 100 sensor)
  - With installed metal plate for fixing perfusion equipment
• Interface board multiboot (IFB-C):
  Interface board with signal processor for real-time signal
  detection and feedback
  Includes various in-/outputs:
  - 16 possible boot images to operate all MCS headstages
of the modular 2100 amplifier suite
  - 16-bit digital input/output channels for TTL integration, 3.3/5 V compatible
(All channels accessible on the backside via Honda-PCS-XE68LFD,
additional bit 0-3 digital in and bit 0-3 digital out accessible on
the front via LEMO EPL.00.250.NTN)
  - Channel definition via software: IFB-Control
(free to download) – Boot image definition
  - 8 analog input channels, +/- 10 V voltage input range
@ 24 bit ADC accessible on the front
(All channels via DIL10Header-100mil, channel 1 and 2
additional via LEMO EPL.00.250.NTN)
  - Audio/stereo out (standard stereo jack 3.5 mm)
  - USB-3.0 type C data transfer to PC (cable included)
  - iX industrial, type B cable for connecting IFB-C to
headstage/signal collector unit/receiver (cable included)
  - DSP-JTAG for direct programming of the built-in DSP
(DIL14Header-100mil-angeled)
  - Physical ground socket (4 mm socket)
  - External power supply included: 24 V/65 W, 110-240 V
• Multiwell Screen and Multi Channel Suite programs:
  - Data acquisition and analysis softwares
  - Including a 2 years maintenance package (software updates
    and support)
• Data acquisition computer:
  - PC with 2 monitors, keyboard and mouse
  - With preinstalled hardware operating system and software
Perfusion kit:
• TC02:
  2-channel temperature controller for biological samples
  - Set-point temperature reached fast within 30 seconds to 5 minutes
  - Control temperature range from ambient temperature to +50 °C
  - Precision controller using PI characteristics
  - 100-240 V input voltage range, external power supply
• TCX_Control Program:
  TCX-Control is a software to control the MCS temperature controllers. Through
  the quick USB interface, it is possible to adjust all settings of the TC01/02
  temperature controller online.
• 1 x PH01:
  - Heatable perfusion cannula with temperature sensor
  - Controlled by TC01/02
• 1 x PPS2:
  - Peristaltic perfusion system with one inlet and one drain pump
  - Controlled by software or touch pad
  - Flow rate: 0 - 30 ml/min
• Perfusion Accessories:
  - 2 magnetic perfusion holders
  - Replacement set of fluidic devices (PPS2-Set-F)
• Accessories:
  - Signal generator for MEA2100-HS60
  - Spare parts
  - USB memory stick with user manuals and software

Technical specifications as specified in the data sheet unless noted otherwise in the order.

References