Schedule a meeting Request a demo MCS Online Shop

www.multichannelsystems.com

Innovations in Electrophysiology

AcadeMEA

Manufacturer: 
Multi Channel Systems MCS GmbH
Made in Germany

AcadeMEA is a compact microelectrode array (MEA) system designed for straightforward acquisition of extracellular signals from neuronal and cardiac preparations. The system combines the MEA2100-Mini headstage (60 or 120 channels) with the eGG USB interface, enabling direct connection to a PC for data acquisition and analysis.

With software-controlled amplification, high-resolution data conversion, and sampling rates up to 50 kHz per channel, AcadeMEA provides a robust platform for electrophysiological recordings in early-stage and routine applications.

System Configuration

 

AcadeMEA Setup

  • MEA2100-Mini headstage (60 or 120 electrodes)
  • eGG USB interface
  • Direct connection to PC via USB-C
  • Multi Channel Systems acquisition and analysis software

This configuration enables a simplified signal pathway from electrode to data acquisition system.

 

Amplifier & Data Acquisition

  • Data resolution: 24 bit
  • Number of channels: 60 or 120
  • Sampling rate per channel: up to 50 kHz
  • Signal input range: ±70 mV
  • Bandwidth: DC to 10 kHz (software controlled)
  • Input impedance: 450 MΩ | 10 µF
  • Input noise: ~0.7 µV RMS

The integrated amplifier and analog-to-digital conversion within the MEA2100-Mini headstage ensure high signal fidelity and stable recordings.

 

eGG USB Interface

  • Connection to headstage: LEMO connector (EPG.0B.307.HLN)
  • Connection to PC: USB-C
  • Dimensions: ~9 cm length, ~4 cm width
  • Operating temperature: 10–50 °C
  • Humidity: 10–80% (non-condensing)

 

MEA2100-Mini Headstage

  • Channel configurations: 60 or 120 electrodes
  • Data resolution: 24 bit
  • Sampling rate: up to 50 kHz/channel
  • Power consumption: 1.5 W
  • Dimensions: 186 × 80 × 12 mm
  • Cable length: 3 m
  • Weight: 485 g

The headstage integrates pre-amplification, filtering, and analog-to-digital conversion, enabling direct electrode access and software-controlled acquisition.

 

Software Compatibility

  • Multi Channel Experimenter: Included
  • Multi Channel DataManager: Included
  • Multi Channel Analyzer: Optional license

 

Environmental & Thermal Control

  • Temperature sensor: Pt100 (4-wire)
  • Accuracy: ±0.1 °C

Compatible with external temperature control systems (e.g., TCX) for stable experimental conditions.

 

Expandability

AcadeMEA is compatible with the Multi Channel Systems ecosystem via the MEA2100-Mini headstage, enabling future system expansion: